Grab bars shall not be provided above the seat.
Ada grab bar height for showers.
The controls shall be placed in an area between 38 48 inches 965 1220 mm above the floor.
Controls shall be located on the back long wall 27 inches 685 mm from the side wall.
In showers and toilets the top of a horizontal grab bar must be 33 36 inches off the floor.
Be very careful when it comes to the height of your grab bars.
Grab bars shall be installed 6 inches 150 mm maximum from adjacent walls.
Where a seat is not provided in standard roll in type shower compartments grab bars shall be provided on three walls.
The controls shall be placed in an area between 38 48 inches 965 1220 mm above the floor.
Grab bars shall be installed 6 inches 150 mm maximum from adjacent walls.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
The controls and spray unit shall be within 18 inches 455 mm of the front of the shower.
Grab bars shall not be provided above the seat.
Figure 608 3 3 grab bars for alternate roll in type showers.
A grab bar 24 inches 610 mm long minimum shall be installed on the control end wall at the front edge of the bathtub.
A folding or non folding seat shall be provided in transfer type shower compartments.
The grab bar or bars shall be 33 36 inches 840 915 mm high.