Latch side clearance is required if the depth is 60 min.
Ada door pull clearance.
A pull that has 10 bottom clearance on the outside of the office is now being used as well this is our interchangeable design.
60 inches 1525 mm 36 inches 915 mm from hinge side.
Handles pulls panic bars.
See image below ada accessible compliant pulls projects.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
Doors shall not be required to comply with the maneuvering clearance requirements in 404 2 4 1 for approaches to the push side of swinging doors.
60 inches 1525 mm 18 inches 455 mm from front.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.
Maneuvering clearances at doors.
Maneuvering clearances at doors.
If you approach a door from the latch side and will need to pull the door open the minimum clearance on the opening side perpendicular to the doorway is 48 inches to allow for the door to open leaving room for a disabled individual to move.
Door or gate side.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding.
The depth can be 54 min.
All doors in alcoves shall comply with the clearances for front approaches.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding doors.
48 inches 1220 mm 0 inches 0 mm 1.
Parallel to doorway beyond latch side unless noted from front.
Maneuvering clearances at doors.
On the pull side of hinge approaches 36 min.
Elevator car and hoistway doors and gates shall be power operated and shall comply with ansi bhma a156 19 1997 or 2002 edition incorporated by reference see.
On the parallel side beyond the latch is 24 inches should the door need to swing open.
If the latch side clearance is at least 42.